FAA Federal Aviation Regulations (FARS, 14 CFR)
FARs > Part 29 > Section 610 - Lightning and static electricity protection
section 29.609 |
section 29.611

(a) The rotorcraft structure must be protected against catastrophic effects from lightning.
(b) For metallic components, compliance with paragraph (a) of this section may be shown by --
(1) Electrically bonding the components properly to the airframe; or
(2) Designing the components so that a strike will not endanger the rotorcraft.
(c) For nonmetallic components, compliance with paragraph (a) of this section may be shown by --
(1) Designing the components to minmize the effect of a strike; or
(2) Incorporating acceptable means of diverting the resulting electrical current to not endanger the rotorcraft.
(d) The electric bonding and protection against lightning and static electricity must --
(1) Minimize the accumulation of electrostatic charge;
(2) Minimize the risk of electric shock to crew, passengers, and service and maintenance personnel using normal precautions;
(3) Provide and electrical return path, under both normal and fault conditions, on rotorcraft having grounded electrical systems; and
(4) Reduce to an acceptable level the effects of lightning and static electricity on the functioning of essential electrical and electronic equipment.
[Amdt. 29-24, 49 FR 44437, Nov. 6, 1984; Amdt. 29-40, 61 FR 21907, May 10, 1996; 61 FR 33963, July 1, 1996]
  
Current page: FARs > Part 29 > Section 610 - Lightning and static electricity protection
section 29.609 |
section 29.611

page stats: viewed 3449 unique times - last change 26-Jan-2005
» DOWNLOADING (PARTS OF) THIS WEBSITE AUTOMATICALLY IS NOT ALLOWED! «
THIS IS NO OFFICIAL SOURCE --
[DISCLAIMER]
[FAA WEBSITE]
See also:
AIM | ATC | FSS | NOTAMS | PCG | |